The tooling allows an operator to fit 7 M3 size inserts into a plastic injection part (defibrillator housing shell).
This tool can be placed on a workplan.
Functioning :
The operator places the 7 inserts in a cavity.
The defibrillator box is placed in its receptacle manually. The receptacle is mounted on an XY-crossing trolley.
A transparent mask is placed on the box to help the operator to target the location of the inserts.
The operator has a free handle vertically.
At the end of this handle, a suction nozzle allows the inserts to be picked up one by one and presented at their insertion point.
The operator presses the two-hand button to insert the M3 insert into the plastic shell.
SPECIFICATIONS :
Download PDF version Reference : 3533
Project added the September 9, 2021