CEREST

Leakage control station

for water-heater cap

Mechanical engineering
Realizations
Cabling
Machines

This stand-alone station is used to check the tightness of the welds of the tappings of a domed bottom of a water heater tank.

The test will be carried out initially at 1 bar and then at 3 bars.

The station is composed of a manually rotating installation and a pneumatic plater arm which acts as a plug and an inflation port.

The operator's safety is ensured by a two-handed button box.

A manual nozzle allows the operator to spray soapy water. To check if there are bubbles, if so this means there is a leak.

A retention tank collects the soapy water. As an HMI, the operator has a button box.

SPECIFICATIONS :

  • Cap end Ø 350 to Ø790 mm
  • Control pressure 1 bar - 3 bars.
Download PDF version Reference : 3789

Project added the October 16, 2024


CEREST

CEREST
20 Rue des Frères Lumiere
68000 Colmar

CEREST

Contact us by e-mail
See our mail adress cerest@cerest.com

CEREST

Contact us by phone
See the phone number +33 (0)3.89.21.02.56